NonStop S-Series Planning and Configuration Guide (G06.26+)
System Components
HP NonStop S-Series Planning and Configuration Guide—523303-017
4-45
Configurations of Memory Units
PMF CRU Compatibility in an Enclosure During Online Replacement or 
Upgrade 
All models of PMF CRUs can be replaced online. Some models of PMF CRUs cannot 
be upgraded online. This table shows which PMF CRUs can be upgraded from one 
model to another online.
.
Alarms When Upgrading from S7400/S72000 to S76000/S86000 or 
S78000/S88000 Servers
When the first 1954 or 1960 PMF CRU in an enclosure is replaced with a 1971, 1972, 
1973, or 1974 PMF CRU, a ServerNet Path Down alarm is generated by OSM or TSM. 
This expected condition is created by router and protocol differences. When the 
second PMF CRU is operational, the system returns to normal, and the alarms 
disappear.
   To 
From 
1950 
7000
1960 
7400
1961 
7600
1962 
7800
1951 
70000
1954 
72000
1970 
74000
1971 
76000
1973 
78000
1972
86000
1974
88000
1950 (S7000)
X
1960 (S7400)
X
O
O O O O O
1961 (S7600)
X O O O O O O
1962 (S7800)
X O O 0 O O
1951 (S70000)
X O O
1954 (S72000)
X O O O O O
1970 (S74000)
X O O O O
1971 (S76000)
X O O O
1973 (S78000)
X O O
1972 (S86000)
X O
1974 (S88000)
X
X. Online replacement and upgrade, same processor
O. Temporary coexistence during upgrade only