NonStop S-Series Planning and Configuration Guide (G06.26+)
Initial Configurations
HP NonStop S-Series Planning and Configuration Guide—523303-017
8-7
Initial Default Values for System Attributes
SYSTEM_LIBRARY_
CODE_FILES
TANDEM^LIBRARY^
CODE^FILES
Change in the 
CONFTEXT file.
SYSTEM_NAME \NONAME Use SCF for the Kernel 
subsystem. See 
Changing System Name 
and Number on 
page 8-8.
SYSTEM _NUMBER 254 Use SCF for the Kernel 
subsystem. See 
Changing System Name 
and Number on 
page 8-8.
SYSTEM_PROCESS_
CODE_FILES
TANDEM^PROCESS^
CODE^FILES
Change in the 
CONFTEXT file.
SYSTEM_PROCESS_
LIBRARY_FILES
TANDEM^PROCESS^
LIBRARY^FILES
Change in the 
CONFTEXT file.
SYSTEM_PROCESS_
MODIFIERS 
Buffer space for operator 
processes
Automatically set to 128 You cannot change an 
automatically configured 
system attribute.
Mode for compatibility 
distributor
- - Use the EMSCCTRL 
commands.
SYSTEM_
PROCESSOR_TYPE
Refer to Processor Types
 on 
page B-12. 
Configured in the 
CONFTEXT file.
SYSTEM_
VOLUME_SUBVOL
$SYSTEM.SYS00 Change in the 
CONFTEXT file.
TAPE_LABEL_PROCESSING For G05.00 and G06.00 
RVUs, the value in the 
CONFTEXT file is ignored 
after the first time you 
change this attribute using 
SCF for the storage 
subsystem. (After G06.00, 
this entry was removed from 
CONFTEXT.)
Use SCF for the storage 
subsystem. 
TIME_LIST_
CONTROL_BLOCKS
Automatically set to 3600 
(before G06.08) or 4400 
(G06.08 and later) 
You cannot change an 
automatically configured 
system attribute.
TIME_ZONE_OFFSET 0:00 (London) Use SCF for the Kernel 
subsystem.
System Attribute Default Value
To Change This 
Attribute  (page2of2)