NonStop S-Series Planning and Configuration Guide (G06.26+)
Terms and Concepts
HP NonStop S-Series Planning and Configuration Guide—523303-017
1-32
TSM Guided Procedures
Add Node to ServerNet Cluster
The OSM equivalent to the Configure ServerNet Node is to use the Add Node to
ServerNet Cluster action from the System object within the OSM Service Connection.
CRU/FRU Replacement
To replace a PMF CRU, IOMF CRU, SEB or MSEB, power supply, ServerNet device
adapter (ServerNet/DA), FCSA, IOAM enclosure, ServerNet switch board, or cluster
switch, perform an action from the OSM Service Connection:
1. Right-click the CRU you want to replace and select Actions
2. Select Replace from the list of available actions
3. Click Perform Action
The Replace action launches a guided procedure, except for the power supply and
FCSA. An interactive action guides you through those replacements.
External Loopback Test
The OSM equivalent to Troubleshoot ServerNet Fabric is the External Loopback Test
action on MSEB or IOMF2 PICs within the OSM Service Connection.
SWAN CLIP Firmware Update
The OSM equivalent to SWAN Fast Firmware Update is to use the Multi-Resource
Actions dialog box in the OSM Service Connection to select, stop, update, and start
the SWAN CLIPs.
Update Topology
The OSM equivalent to Add Switch is to use the Update Topology action from the
ServerNet Cluster object within the OSM Service Connection.
TSM Guided Procedures
If you use TSM, you must use a system console to receive event messages or alarms
that are generated for problems related to CRUs. For information on the TSM package,
see the TSM Online User Guide.
For information on the compatibility of TSM product versions with system software,
refer to the NonStop System Console Installer Guide.