NonStop S-Series Planning and Configuration Guide (G06.28+)
HP NonStop S-Series Planning and Configuration Guide—523303-020
14-1
14 Planning for CRU Replacement
When you replace a CRU online, you must prepare all elements in the system that are 
affected by the removal of that CRU, such as other CRUs and processes. Use the 
procedure in this section and worksheets to determine which components of a system 
are affected by removal of a PMF CRU, SEB, or MSEB. 
To replace a PMF CRU, SEB, or MSEB, you must use a guided replacement tool which 
automatically detects the affected components and prepares the system for CRU 
replacement. See the Service Management Packages on page 1-35 for guided 
replacement tools which contain online help topics. 
For more information about the pathways, see ServerNet Communication Pathways on 
page 6-1. 
ServerNet Communication Pathways 
Worksheets
The ServerNet communication pathways worksheets help you trace the ServerNet 
communication pathways in your system so that you can determine which components 
and enclosures would be affected by the removal of a PMF CRU, SEB, or MSEB. 
Copy the appropriate worksheets from Appendix C, Blank Forms. 
ServerNet Communication Pathways Worksheets 14-1
Completing the Worksheets   14-3
System 
Topology
Copy These Worksheets
Tetra 8 ServerNet Communication Pathways: Tetra 8 Topology
Tetra 16 ServerNet Communication Pathways: Tetra 16 Topology, X Fabric 
or 
ServerNet Communication Pathways: Tetra 16 Topology, Y Fabric
Note. The worksheets illustrate the maximum configuration of each topology; your system 
might contain fewer components or enclosures.