Maximum Time That an Appearance-Side Door Can
Be Open
This figure shows the cooling fans:
Maximum Time That an Appearance-Side Door Can Be Open
This table shows the amount of time that components in a fully loaded enclosure, with
the appearance-side enclosure door open and only one fan operating, can operate
before overheating:
Ambient Room Temperature
Altitude 25 °C (77 °F) 30 °C (86 °F) 35 °C (95 °F) 38 °C (100 °F)
Sea level >45 minutes 36 minutes 21 minutes 13 minutes
5,000 feet
(1524 meters) 38 minutes 22 minutes 13 minutes 8 minutes
10,000 feet
(3048 meters) 25 minutes
14 minutes 10 minutes 5 minutes