NonStop S-Series Planning and Configuration Guide (G06.29+)

System Components
HP NonStop S-Series Planning and Configuration Guide523303-021
4-14
Power Shelf
Power Shelf
The type of CRU installed in slots 50 and 55 determines whether that enclosure
requires a power shelf. Enclosures without power shelves have power supplies internal
to the CRUs in slots 50 and 55. Enclosures with power shelves have external power
supplies.
The power shelf is installed under the enclosure chassis.
AC power is supplied to the power shelf through AC power cords that connect to the
power supply through the sheet-metal bulkhead in the center of the power shelf. AC
power for enclosures without power shelves is provided by AC power cords connected
directly to the PMF CRUs or IOMF CRUs.
CRU Model Server Type
Does Not Require
Power Shelf
Requires Power
Shelf
S74 X
S76 X
S78 X
S78B X
S700 X (with NSR-W) X (with NSR-G or
NSR-T)
S740 X
S760 X
1950 PMF S7000 X
1960 PMF S7400 X
1961 PMF S7600 X
1962 PMF S7800 X
1975 PMF S7800B X
1951 PMF S70000 X
1954 PMF S72000 X
1970 PMF S74000 X
1971 PMF S76000 X
1973 PMF S78000 X
1972 PMF S86000 X
1974 PMF S88000 X
1952 IOMF All servers X
1980 IOMF 2 All Servers X