NonStop S-Series Planning and Configuration Guide (G06.29+)

Planning for LAN Communications
HP NonStop S-Series Planning and Configuration Guide523303-021
11-2
Dedicated LAN for SWAN Concentrators
Dedicated LAN for SWAN Concentrators
The dedicated LAN for SWAN concentrators can connect only to SWAN or SWAN 2
concentrators, the Ethernet ports on E4SAs and FESAs that connect to the SWAN
concentrators, and Ethernet switches or hubs provided by HP.
Secure Operations LANs
A secure operations LAN can connect to many clients and servers and might or might
not be connected to routers and bridges. NonStop S-series servers can connect to
secure operations LANs using E4SA Ethernet ports that are not connected to SWAN
concentrators. Routers and bridges are supported for SWAN concentrators beginning
on the G06.06 RVU.
For more information on the secure operations LAN, see the NonStop S-Series
Hardware Installation and FastPath Guide or the TSM Configuration Guide.
Note. System consoles can be connected to a secure operations LAN that connects to the
Ethernet ports on an E4SA, FESA, GESA, or G4SA. This LAN configuration provides extra
flexibility in placing system consoles but does not replace the dedicated service LAN, which is
required for use of Low-Level Link and Notification Director applications in OSM or TSM. See
Dedicated Service LAN for OSM or TSM
on page 11-1.