NonStop S-Series Planning and Configuration Guide (G06.29+)

Terms and Concepts
HP NonStop S-Series Planning and Configuration Guide523303-021
1-4
Peripheral Enclosure
IOAM enclosures connect to an MSEB of S76000 and later NonStop S-series systems
and can be installed in place of I/O enclosure in groups 11, 12, 13, 14, or 15. I/O
enclosures and IOAM enclosures can coexist in the same system.
For more information, see IOAM Enclosures on page 4-68 or the Modular I/O
Installation and Configuration Guide.
Peripheral Enclosure
A peripheral enclosure is an enclosure that contains components related to peripheral
devices.
Cluster Switch Enclosure
The cluster switch enclosure is half the height of a standard NonStop S-series system
enclosure. It houses ServerNet cluster components:
Visual Image Package
Starting with NonStop S76000 servers, a visual image package, with tall front and rear
enclosure doors and side panels, is standard. Enclosures with short front doors and no
side panels can be ordered as an option for NonStop S76000 and S86000 servers for
one year after the G06.16 RVU. Kits for the visual image package are also available for
upgrading enclosures.
The visual image package includes:
Appearance-side door that is taller than the original door and so takes the place of
the original and the power-shelf panel located beneath it
Service-side door that looks like the appearance-side door but does not have the
EMI features of the appearance-side door
Side panels that fit in the space between the vertical frame rails on the end
enclosures in a row
Power Shelf
A power shelf is an assembly residing below the chassis housing two power supplies
and supporting circuitry.