NonStop S-Series Planning and Configuration Guide (G06.29+)

Specifications
HP NonStop S-Series Planning and Configuration Guide523303-021
B-4
ServerNet Cables for Same-Row Connections
SEB-to-SEB Connections in Same Row
You need these ServerNet cables for each SEB-to-SEB connection within a row of
enclosures..
Note. Part numbers for these cables are located in the NTL Hardware Service and
Maintenance collection. In NTL, select: NTL Support and Service> Service Information> Part
Numbers.
Arrangement of
Enclosures
Distance Between
Connections Cable Length Required
Spaced Feet Meters Feet Meters
Vertically
0 8.2 2.5 8.2 2.5
Horizontally
0 5.2 1.6 5.2 1.6
1 7.5 2.3 8.2 2.5
2 9.4 2.9 9.8 3.0
3 11.2 3.4 13.1 4.0
4 13.1 4.0 13.1 4.0
5 14.9 4.5 16.4 5.0
6 16.7 5.0 19.7 6.0
7 18.6 5.7 19.7 6.0
8 20.4 6.2 23.0 7.0
9 22.2 6.8 23.0 7.0
10 24.1 7.3 26.2 8.0
Diagonally
0 8.2 2.5 8.2 2.5
1 112 3.4 13.1 4.0
2 13.1 4.0 13.1 4.0
3 14.8 4.5 16.4 5.0
4 16.7 5.1 19.7 6.0
5 18.5 5.6 19.7 6.0
6 20.3 6.2 23.0 7.0
7 22.2 6.8 23.0 7.0
8 24.0 7.3 26.2 8.0
9 25.9 7.9 26.2 8.0
10 27.7 8.4 29.5 9.0