NonStop S-Series Planning and Configuration Guide (G06.29+)

Specifications
HP NonStop S-Series Planning and Configuration Guide523303-021
B-5
ServerNet Cables for Same-Row Connections
SEB-to-IOMF CRU Connections in Same Row
You need these ServerNet cables for each SEB-to-IOMF-CRU or MSEB-to-IOMF CRU
connection within a row of enclosures.
n
Note. Part numbers for these cables are located in the NTL Hardware Service and
Maintenance collection. In NTL, select: NTL Support and Service> Service Information> Part
Numbers.
Arrangement of
Enclosures
Distance Between
Connections Cable Length Required
Spaced Feet Meters Feet Meters
Vertically
0 8.2 2.5 8.2 2.5
Horizontally
0 6.2 1.9 8.2 2.5
1 8.2 2.5 8.2 2.5
2 10.0 3.1 9.8 3.0
3 11.9 3.6 13.1 4.0
4 13.7 4.2 16.4 5.0
5 15.6 4.7 16.4 5.0
6 17.4 5.3 19.7 6.0
7 19.2 5.9 19.7 6.0
8 21.1 6.4 23.0 7.0
9 22.9 7.0 23.0 7.0
10 24.7 7.5 26.2 8.0
Diagonally
0 9.5 2.9 9.8 3.0
1 11.5 3.5 13.1 4.0
2 13.3 4.1 16.4 5.0
3 15.2 4.6 16.4 5.0
4 17.0 5.2 19.7 6.0
5 18.8 5.7 19.7 6.0
6 20.7 6.3 23.0 7.0
7 22.5 6.9 23.0 7.0
8 24.3 7.4 26.2 8.0
9 26.2 8.0 26.2 8.0
10 28.0 8.5 29.5 9.0