NonStop S-Series Planning and Configuration Guide (G06.29+)

Terms and Concepts
HP NonStop S-Series Planning and Configuration Guide523303-021
1-15
Components in NonStop S76000, S86000, and Later
Configurations
Components in NonStop S76000, S86000, and Later
Configurations
NonStop S76000 and S86000 servers use the G06.16 RVU and later. The
NonStop S88000 uses the G06.24 RVU and later. The S7800B uses the G06.25 RVU
and later. These conditions apply to the NonStop S7800, S7800B, S76000, S86000,
and later servers:
MSEBs are required in slots 51 and 52 of all processor enclosures, 01 through 08.
MSEBs (or SEBs) can be used in slots 53 and 54 of processor enclosures 01
through 04.
ServerNet cabling between system enclosures uses either serial-copper or fiber-
optic cables.
No ECL cable adapters are allowed.
To perform an online memory dump (using RECEIVEDUMP or RCVDUMP) of a
processor with 16 GB processor to a disk volume, you must have one 36 GB disk drive
in which 20 GB is reserved for memory dump. The remaining 16 GB can be used for
anything. This disk does not have to be $SYSTEM.
You must use one of these tape drives attached to enclosure 01 and a tape cartridge
with a capacity of at least 20 GB:
5157, 5157ACL, and 5158ACL tape drives using DLT-IV tape cartridges
CT9840-3 tape drive using a 9840 tape cartridge
CT9841-x tape drive using a 9841 tape cartridge in a tape library
5257, 5257ACL and 5258ACL using a Super DLT tape cartridge
N1524A LTO tape drive