NonStop S-Series Server Description Manual (G06.27+)
TNS Instruction Set Definition
HP NonStop S-Series Server Description Manual—520331-004
C-39
Instruction Definitions
0 0 0 4 5 6* DDTX DDT request
 A.<12:15>=request
 %004 = Enable XRAY sampler interrupts - TXP,VLX
 %005 = Disable XRAY sampler interrupts- TXP,VLX
 %020-%037 =Set diag flags with RUN bit-VLX only
 issue DDT request;
 if timeout then
 {N:=1; Z:=0}
 else
 {N:=0; Z:=1};
 RP:=RP-1
0 0 0 4 6 1* RUS  read micro state information
 RP:=RP-5
0 0 0 4 7 1  ESE  extensible stack entry
 A: expected-arguments word count
 if (xmem[Lx-$XADR(3)]+A)=0 then
 RP := 7
 else
 {cc(RP-1);
 DPCL(sysstack[%171]);
 RP := 7
 cc and k now undefined
 }
 [ See Note 1: CALLABLE PRIV ]
0 0 0 5 0 0* XADD XRAY counter add
 D=parameter
 CB=ext addr
 A=counter offset
 'Indivisible On';
 t := xmem2[CB];
 if t.<0> then
 {a := t + $XADR(A);
 ! add parameter
 xmem2[a]:=xmem2[a] + $DBL(D);
 xmem[t] := 0;
 }
 'Indivisible Off';
 RP:=RP-4;
 ** The counters must be present in memory 
Table C-2. Instruction Definitions (page29of38)