NonStop S-Series System Expansion and Reduction Guide
Table Of Contents
- NonStop S-Series System Expansion and Reduction Guide
- What’s New in This Guide
- About This Guide
- 1 The Resizing Process
- 2 Planning System Expansion
- 3 Planning System Reduction
- 4 Reducing a System Online
- 1.Prepare the Donor System for Reduction
- 2.Record Information About the Donor System
- 3.Prepare Both ServerNet Fabrics
- 4.Inventory Enclosures to Be Removed
- 5.Prepare and Stop Devices and Processes
- 6.Ensure Devices and Processes Are Stopped
- 7.Delete Devices and Processes If Necessary
- 8.Prepare Enclosures for Removal
- 9.Finish the Reduction
- 10.Remove Other Cables From Powered-Off Enclosures
- 11.Physically Remove Enclosures From the System
- Adding Enclosures to Another System
- 5 Reducing a System Offline
- 6 Expanding a System Online
- Preparation for Online Expansion
- 1.Prepare Target System for Expansion
- 2.Record Information About Target System
- 3.Prepare Target System for Addition of Block
- 4.Save Current Target System Configuration
- 5.Copy SP Firmware File From the Target System to the System Console
- 6.Finish Gathering Information
- 7.Connect a System Console to the Enclosure
- 8.Change Group Number of Enclosure to 01
- 9.Power On Enclosure
- 10.Verify Connection Between System Console and Enclosure
- 11.Configure System Console and Enclosure
- 12.Verify SP Firmware Is Compatible
- 13.Update SP Firmware in Enclosure If Necessary
- 14.Configure Topology of Enclosure If Necessary
- 15.Power Off Enclosure
- 16.Repeat Steps 6 Through 15 If Necessary
- 17.Assemble Enclosures Into a Block
- 18.Change Group Numbers of Block to Fit Target System
- 19.Disconnect System Console From Block
- 20.Power On Added Block
- 21.Cable Block to Target System
- 22.Verify Resized Target System
- 23a.Update Firmware and Code in Block (Using TSM)
- 23b.Update Firmware and Code in Block (Using OSM)
- 24.Reload Processors in Block If Necessary
- 25.Verify Operations in Added Block
- 26.Configure CRUs in Added Block
- 7 Troubleshooting
- A Common System Operations
- Determine the Processor Type
- Determine the ServerNet Fabric Status
- Determine the Product Versions of the OSM Client Software
- Determine the Product Version of the TSM Client Software
- Move the System Console
- Stop the OSM or TSM Low-Level Link
- Start a Startup TACL Session
- Start the OSM or TSM Low-Level Link
- Start the OSM Service Connection or TSM Service Application
- B ServerNet Cabling
- C Checklists and Worksheets
- D Stopping Devices and Processes
- Safety and Compliance
- Glossary
- Index

Expanding a System Online
HP NonStop S-Series System Expansion and Reduction Guide—522465-009
6-25
17.1 Cable Enclosures Together
Figure 6-3. ServerNet Cable Connections for a Multiple-Enclosure Block
Caution. ServerNet cabling for IOAM enclosures is different from the cabling shown in this
diagram. Only service providers trained by HP should perform cabling of IOAM enclosures.
Tetra 16 Topology, Y
Fabric
PMF
50
Group
01
5
4
6
1
2
3
SEB
51
Tetra 8 Topology, X
Fabric
PMF
55
Group
01
5
4
6
1
2
3
SEB
52
Tetra 8 Topology, Y
Fabric
Tetra 16 Topology, X
Fabric
Group
12
IOMF
50
Group
11
IOMF
50
Group
12
IOMF
55
Group
11
IOMF
55
PMF
50
SEB
53
Group
01
5
4
6
1
2
3
654321
SEB
51
50
Group
11
IOMF
50
Group
12
IOMF
Group
13
IOMF
50
Group
14
IOMF
50
Group
15
IOMF
50
PMF
55
SEB
54
Group
01
5
4
6
1
2
3
654321
SEB
52
55
Group
11
IOMF
55
Group
12
IOMF
Group
13
IOMF
55
Group
14
IOMF
55
Group
15
IOMF
55
VST116.vsd