NonStop S-Series System Expansion and Reduction Guide

Table Of Contents
Planning System Expansion
HP NonStop S-Series System Expansion and Reduction Guide522465-009
2-10
Example of Choosing a Block Structure
Example Step 2: Eliminate Unsupported Enclosures
Consult your service provider about how many I/O enclosures are supported for the
RVU running on your system. This example assumes that you are reconfiguring a
NonStop Sxx000 system that supports 36 I/O enclosures, so you mark off the
unsupported I/O enclosures as shown.
Group 45
IOMF
50
50
50
50
50
3
2
1
4
5
6
SEB
51
1 23
4
5
6
SEB 53
PMF 50
6543 2 1
SEB
51
SEB 53
PMF 50
6
5
4
1
2
3
50
50
50
50
50
6
5432
1
SEB
51
SEB 53
PMF 50
1
2
3
4
5
6
50 50
50 50
SEB 53
SEB
51
1
2
3
4
5
6
PMF 50
3456
50
Group
52
IOMF
50
50
50
Group 55
IOMF
50
Group 56
IOMF
50
Group 57
IOMF
50
Group 58
IOMF
50
Group 59
IOMF
50
Group 11
IOMF
50
Group 12
IOMF
50
Group 13
IOMF
50
Group 14
IOMF
50
Group 15
IOMF
50
SEB 53
SEB
51
6
5
4
1
2
3
PMF 50
Group
01
1 234
5
6
6
5
4
3
2
1
SEB
51
1234
5
6
SEB 53
PMF 50
50
50
50
50
50
50
SEB
51
6
5
43 21
SEB 53
PMF 50
6
5
4
3
2
1
Group
74
IOMF
50
50 50
SEB
51
6
SEB 53
PMF 50
3
2
1
4
5
6
50
50
50
50
50
Added Blocks — Tetra 16 Topology, X Fabric
Worksheet 5
Shade in the enclosures, ports, and slot numbers that are in use in your current configuration.
You can now see the available locations and group numbers for added enclosures.
With a highlighter or a pen of a different color, circle where you will add the enclosures.
VST212.vsd
VST402.v
Group
53
IOMF
Group
53
IOMF
Group
64
IOMF
Group
63
IOMF
Group
62
IOMF
Group
61
IOMF
Group
51
IOMF
Group
05
Group 44
IOMF
Group 43
IOMF
Group 42
IOMF
Group 41
IOMF
50
Group 89
IOMF
Group
04
50
Group 85
IOMF
50
Group 86
IOMF
50
Group 87
IOMF
50
Group 88
IOMF
Group
08
Group
81
IOMF
50
Group
82
IOMF
50
Group
83
IOMF
50
Group
84
IOMF
1
2
34
5
Group
72
IOMF
Group
71
IOMF
Group 79
IOMF
Group 78
IOMF
Group 77
IOMF
Group 76
IOMF
Group 75
IOMF
Group
07
50
Group
73
IOMF
Group
03
Group 65
IOMF
Group 66
IOMF
Group 67
IOMF
Group 68
IOMF
Group 69
IOMF
Group
06
Group
02
Group 21
IOMF
Group 22
IOMF
Group 23
IOMF
Group 24
IOMF
Group 25
IOMF
50
Group 31
IOMF
50
Group 32
IOMF
50
Group 33
IOMF
50
Group 34
IOMF
50
Group 35
IOMF
Note. This illustration
shows the maximum
possible number of I/O
enclosures. Your
service provider can tell
you the number of I/O
enclosures supported
by the RVU running on
your system.
Note. If your target
system is a Tetra 8
topology with the
maximum number of
enclosures attached,
you cannot expand it
online. You must
reconfigure it as a Tetra
16 topology offline.