NonStop Software Essentials User's Guide

Example 19-1 Example TRACEINI File
[CBEXE]
Level-1 On
Level-2 On
Level-3 On
Level-4 On
[ISEXE]
Level-1 On *INPUT*
Level-2 On *
Level-3 On *
Level-4 On *
Level-5 On *
[TAEXE]
Level-1 On *210*
Level-2 On
Level-3 Off
Level-4 Off
Level-5 Off
In this example:
All tracing is enabled for the Configuration Builder. (Level 5 is on by default.)
All tracing is enabled for the Input Supervisor for any information matching the indicated
strings.
For the Target Activator, tracing is enabled for levels 1 and 2, and level 1 has a selective
requirement of including 210.
Search StringActivity
STG_CB_*[CBEXE]
STAGE_SNAPSHOT_*[ISEXE]
[OMEXE]
[SMEXE]
STG_AP_*[TAEXE]
STG_BK_*
STG_IA_*
STG_VD_*
STG_GP_*
Table 19-1 (page 197) shows search string examples that can be used.
Table 19-1 Search String Examples
Stage 3Stage 2Stage 1Activity
"STG_CB_DECIDE_FOR_SRLS(10)"CB_STAGE_1
"STG_CB_RETRIEVE_SRL_BLD_TOOLS(20)"
"STG_CB_RETRIEVE_SRL_BLD_RELOCS(27)"
"STG_CB_RETRIEVE_SRL_ZTILT_SOURCE(34)"
"STG_CB_BUILD_NSKCOM_INPUT_FILE(41)"
Running Traces on DSM/SCM Components 197