ODBC Server Messages Manual
TACL Messages
NonStop ODBC Server Messages Manual—429394.001
3-4
Recovery. Check that the value for PROCESS-NAME in the configuration file is a
valid process name. See Correct Name Formats on page 2-1 for the format for process
names. Correct the value and reissue the start command.
35138
Cause. The value for the CPU-PRIMARY parameter in the configuration file is not
numeric.
Effect. SCS fails to start.
Recovery. Change the CPU-PRIMARY parameter in the configuration file so that it is
a number in the range from 0 to 15. Reissue the start command.
35139
Cause. The value for the CPU-PRIMARY parameter in the configuration file is not a
valid processor number between 0 and 15.
Effect. SCS fails to start.
Recovery. Change the CPU-PRIMARY parameter in the configuration file to be a
number in the range from 0 to 15. Reissue the start command.
35140
Cause. The value for the CPU-BACKUP parameter in the configuration file is not
numeric.
Effect. SCS fails to start.
Recovery. Change the CPU-BACKUP parameter in the configuration file to be a
number in the range from 0 to 15. Reissue the start command.
35141
Cause. The value for the CPU-BACKUP parameter in the configuration file is not a
valid processor number between 0 and 15.
Effect. SCS fails to start.
Recovery. Change the CPU-BACKUP parameter in the configuration file to be a
number in the range from 0 to 15. Reissue the start command.
The value specified for the SQLCS CPU-PRIMARY is not a number
CPU-PRIMARY specified for SQLCS process is not 0-15
The value specified for the SQLCS CPU-BACKUP is not a number
CPU-BACKUP specified for SQLCS process is not 0-15