OmniMessaging EMS Operator's Manual 1.8
OmniMessaging EMS Operator’s Guide 
Opsol Confidential and Proprietary       23
EMS Message: 02-07-02 09:58:47 \NSK.$Y1XW TANDEM.NSIM.G06 000203 OMNI 
Process MTA: Out Of Memory \NSK.$Y1XW Unable to allocate message list control block Pathmon: 
\NSK.$OMNID 
Cause: Memory could not be allocated to a block. Possible memory leak. 
Corrective Action: The server will abend. Pass the saveabend to the OmniMessaging representative. 
EMS Message: 02-07-02 09:58:47 \NSK.$Y1XW TANDEM.NSIM.G06 000203 OMNI 
Process MTA: Out Of Memory \NSK.$Y1XW Unable to allocate context control block Pathmon: 
\NSK.$OMNID 
Cause: Memory could not be allocated to a block. Possible memory leak. 
Corrective Action: The server will abend. Pass the saveabend to the OmniMessaging representative. 
EMS Message: 02-07-02 09:58:47 \NSK.$Y1XW TANDEM.NSIM.G06 000203 OMNI 
Process MTA: Out Of Memory \NSK.$Y1XW Unable to allocate context ext control block Pathmon: 
\NSK.$OMNID 
Cause: Memory could not be allocated to a block. Possible memory leak. 
Corrective Action: The server will abend. Pass the saveabend to the OmniMessaging representative. 
EMS Message: 02-07-02 09:58:47 \NSK.$Y1XW TANDEM.NSIM.G06 000203 OMNI 
Process MTA: Out Of Memory \NSK.$Y1XW Unable to allocate SMTP-IIS context. Pathmon: \NSK.$OMNID 
Cause: Memory could not be allocated for Inter-instance context buffer. Possible memory leak. 
Corrective Action: The server will abend. Pass the saveabend to the OmniMessaging representative. 
EMS Message: 02-07-02 09:58:47 \NSK.$Y1XW TANDEM.NSIM.G06 000203 OMNI 
Process MTA: Out Of Memory \NSK.$Y1XW Unable to allocate SMTP context. Pathmon: \NSK.$OMNID 
Cause: Memory could not be allocated for Inter-instance context buffer. Possible memory leak. 
Corrective Action: The server will abend. Pass the saveabend to the OmniMessaging representative. 
EMS Message: 02-07-02 09:58:47 \NSK.$Y1XW TANDEM.NSIM.G06 000203 OMNI 
Process MTA: Out Of Memory \NSK.$Y1XW Unable to allocate SMTP lineRecv context. Pathmon: 
\NSK.$OMNID 
Cause: Memory could not be allocated for Inter-instance context buffer. Possible memory leak. 
Corrective Action: The server will abend. Pass the saveabend to the OmniMessaging representative. 
EMS Message: 02-03-23 17:23:21 \NSK.$Z4QZ  TANDEM.NSIM.G06 000203 OMNI Process MTA 
:Out Of Memory \NSK.$Z4QZ: SENDMSG memory allocation failure. Pathmon: NSK.$IMAP7  
Cause:  Memory insufficient for program to execute. 
Corrective Action: Contact system Administrator. Try to reduce no. of processes running. 
EMS Message: 02-07-02 09:58:47 \S702WEB.$Y1XW TANDEM.NSIM.G06 000203 OMNI Process MTA: 
Out Of Memory \S702WEB.$Y1XW <SML Module memory allocation failure> Pathmon: 
\S702WEB.$OMNID  
Cause: Could not allocate memory. 
Recovery: No action needed. 
2.5  EMS Message 204 
This EMS event is displayed in the primary collector. 
EMS Message: 02-08-08 22:28:17 \NMA004.$SG55 TANDEM.NSIM.G06 000204 OMNI  
Process RELAY \NMA004.$SG55 Internal Module Error <error> Module code 0, *ERROR* :Invalid DNS 
Request ID in recv_over Pathmon: \NMA004.$IMAP0 
Cause: Communication error between Relay server and DNS. 
Corrective Action: None. Informational message. 
2.6  EMS Message 205 
This EMS event is displayed in the primary collector. 
EMS Message: 02-07-02 10:03:49 \NSK.$Y1YA TANDEM.NSIM.G06 000205 Process 
MTA \NSK.$Y1YA Initialization Error <error> The max recv associations value out of range. Pathmon: 
\NSK.$OMNID 