Corrective Action: Contact Opsol representative. 
EMS Message: 02-08-02 00:51:29 \NMA004.$STBC TANDEM.NSIM.G06 000208 OMNI  
Process RELAYD \NMA004.$STBC: Server Warning <error> Server abending: Relay Recipient doesn't exist  
Pathmon: \NMA004.$IMAP6 
Cause: Servers abended because relay recipient does not exist. 
Corrective Action: Contact Opsol representative. 
EMS Message: 02-06-19 15:34:09 \NITRO.$IVMH   TANDEM.NSIM.G06 000208 OMNI  
Process RELAYD \NITRO.$IVMH: Server Warning <error> Invalid NSIM-X-MTA-LONG-RETRY-INTERVAL 
value,using default 240 minutes Pathmon: \NITRO.$IMAPI 
Cause: Wrong parameter value specified. 
Corrective Action: Correct the server parameter value. 
EMS Message: 02-08-27 14:45:45 \NMA003.$SE33  TANDEM.NSIM.G06  000208 OMNI  
Process RELAYD \NMA003.$SE33: Server Warning <error> ABORTTRANSACTION Called Successfully  
Pathmon: \NMA003.$IMAP0 
Cause: When an abort transaction called successfully. 
Corrective Action: Informational message. 
EMS Message: 02-05-15 00:00:00 \NMA002.$DSN6 TANDEM.NSIM.G06 000208 OMNI  
Process MTADIST \NMA002.$DSN6: Server Warning <error> New connection queue is full. current 
connection_queue_length = 1024 Pathmon: \NMA002.$IMAP6 
Cause: Distributor queue to accept new connections is full. 
Corrective Action: Increase number of In-MTAs. 
EMS Message: 02-05-15 00:00:00 \NMA002.$DSN6 TANDEM.NSIM.G06 000208 OMNI  
Process MTADIST \NMA002.$DSN6: Server Warning <error> Connection close routine call: CANCELREQ 
failed Pathmon: \NMA002.$IMAP6 
Cause: Guardian procedure CANCELREQ failed. 
Corrective Action: Informational message. 
EMS Message: 02-07-02 12:08:02 \NMA001.$MAA3 TANDEM.NSIM.G06 000208 OMNI 
Process MTA \NMA001.$MAA3: Server Warning <error> Event bounds check in SMTP state machine 
Pathmon: \NMA001.$IMAP6 
Cause: Severe internal error in MTA. 
Corrective Action: Contact Opsol representative. 
EMS Message: 02-06-26 10:30:02 \ATOM.$YG41  TANDEM.NSIM.G06  000208 OMNI 
Process RELAY \ATOM.$YG41: Server Warning <error> Connect failure E 10 D 0 Domain: 
jpbcsu2.tko.cpqcorp.net Pathmon: \ATOM.$Z28FL 
Cause: Relay server could not connect to the MTA of the specified domain. 
Corrective Action: None. Informational message. 
EMS Message: 02-03-23 17:23:21 \NSK.$Z4QZ TANDEM.NSIM.G06  000208 OMNI Process MTA 
\NSK.$Z4QZ: Server Warning <filesystem error> Error <error> in allocating space 
Pathmon: NSK.$IMAP7  
Cause:  Error in allocating space 
Corrective Action: Contact OmniMessaging support 
EMS Message: 02-03-23 17:23:21 \NSK.$Z4QZ  TANDEM.NSIM.G06 000208 OMNI Process MTA 
\NSK.$Z4QZ: Server Warning <error> Error <error> in defining space 
Pathmon: NSK.$IMAP7  
Cause:  Error in defining the space 
Corrective Action: Contact OmniMessaging support 
EMS Message: 02-03-23 17:23:21 \NSK.$Z4QZ TANDEM.NSIM.G06 000208 OMNI Process MTA 
\NSK.$Z4QZ: Server Warning <error> Space <number> has association = <association id> 
Pathmon: NSK.$IMAP7  
Cause:  This is an informational message.  
Corrective Action: Contact OmniMessaging support 
EMS Message: 02-03-23 17:23:21 \NSK.$Z4QZ TANDEM.NSIM.G06 000208 OMNI Process MTA 
\NSK.$Z4QZ: Server Warning <error> Space <number> has identifier = <identifier string> 
Pathmon: NSK.$IMAP7  