EMS Message: 03-06-12 02:00:31 \OMNI.$X3H4 TANDEM.NSIM.G06 000202 OMNI Process
ADAPTOR \OMNI.$X3H4 I/O Error: File System Error <error> File Name <filename>, Sendmsg Quit
failed Pathmon: \OMNI.$OMNI1
Cause: The Sendmsg Quit call failed.
Corrective Action: Contact OmniMessaging support.
EMS Message: 03-06-12 02:00:31 \OMNI.$X3H4 TANDEM.NSIM.G06 000202 OMNI Process
ADAPTOR \OMNI.$X3H4 I/O Error: File System Error <error> File Name <filename>, Invalid last
state Pathmon: \OMNI.$OMNI1
Cause: This is an internal error.
Corrective Action: Contact OmniMessaging support.
9.4 EMS Message 203
This EMS event is displayed in the primary collector.
EMS Message: 02-07-02 09:58:47 \S702WEB.$Y1XW TANDEM.NSIM.G06 000203 OMNI Process
ADAPTOR : Out Of Memory \S702WEB.$Y1XW Unable to allocate ADAPTOR context. Pathmon:
\S702WEB.$OMNI5
Cause: Unable to allocate memory for the user-process.
Corrective Action: Check up system configuration and if the problem persists contact OmniMessaging
support.
EMS Message: 02-07-02 09:58:47 \S702WEB.$Y1XW TANDEM.NSIM.G06 000203 OMNI Process
ADAPTOR : Out Of Memory \S702WEB.$Y1XW Unable to allocate global data block. Pathmon:
\S702WEB.$OMNI5
Cause: Unable to allocate memory for the user-process.
Corrective Action: Check up system configuration and if the problem persists contact OmniMessaging
support.
9.5 EMS Message 204
This EMS event is displayed in the primary collector.
EMS Message: 02-07-02 10:09:38 \S702WEB.$Y1YP TANDEM.NSIM.G06 000204 OMNI Process
ADAPTOR \S702WEB.$Y1YP Internal Module Error <error> Module code <__LINE__>, <filename>,
Negative session count. Pathmon: \S702WEB.$OMNI5
Cause: Session count has negative value. The Module code is the portion of the code where the error
occurred.
Corrective Action: Unexpected value for session count. Check up the server configuration for NSIM-
ZLEADAPT-MAX-SESSION param, and if the problem persists contact OmniMessaging Support.
9.6 EMS Message 205
This EMS event is displayed in the primary collector.
EMS Message: 02-07-02 10:03:49 \S702WEB.$Y1YA TANDEM.NSIM.G06 000205 Process
ADAPTOR \S702WEB.$Y1YA Initialization Error <error> The NSIM-HOST-NAME parameter must be
specified. Pathmon: \S702WEB.$OMNI5
Cause: Host name not found in server params.
Corrective Action: Check up the server configuration, and correct the NSIM-HOST-NAME server param.
EMS Message: 02-07-02 10:03:49 \S702WEB.$Y1YA TANDEM.NSIM.G06 000205 Process
ADAPTOR \S702WEB.$Y1YA Initialization Error <error> The server class name must be specified.
Pathmon: \S702WEB.$OMNI5
Cause: The server class name not found in server params.
Corrective Action: Check up the server configuration, and correct the NSIM-SERVER-CLASS param.