Open System Services Management and Operations Guide (G06.25+, H06.03+)
Open System Services Monitor
Open System Services Management and Operations Guide—527191-002
12-55
INFO SERVER Command
maxmsg
specifies the maximum number of messages allowed on all OSS message queues
on a system. Valid values are in the range 1 through 16384.
This parameter is valid only for OSS message-queue servers.
msgmsize
specifies the maximum number of bytes allowed for a message. Valid values are in
the range 1 through 32000.
This parameter is valid only for OSS message queue-servers.
choice
specifies whether the server can be started in its backup processor during a restart
when its primary processor is unavailable. Valid values are TRUE or FALSE.
seconds
specifies the number of seconds that the OSS Monitor waits for the server’s
primary processor to become available during an automatic restart. Valid values
are 0 through 600.
state
specifies the desired state of the server after the next time the automatic startup
service is used. Valid values are STARTED or STOPPED.
tries1
specifies the number of times that the OSS Monitor attempts to restart the server
when the automatic startup service is used. Valid values are 0 through 10.
tries2
specifies the number of times that the OSS Monitor actually restarted the server
during the previous 10 minutes.
Example
To obtain a detailed report of the configuration of the server $ZPNS and send
informational messages to the file CMDLOG, enter the following command:
INFO /OUT CMDLOG/ SERVER $ZPMON.#ZPNS, DETAIL