Open System Services Management and Operations Guide (G06.25+, H06.03+)
Open System Services Monitor
Open System Services Management and Operations Guide—527191-002
12-79
STATUS SERVER Command
The information returned for a detailed report has this format:
server-devicename
is the server name of the server whose status is being displayed, shown as a
device of the OSS Monitor process.
state
is the state of the server. The value is one of the following:
time1
is the timestamp for the time when the server was last started, in the form
dd mmm yyyy hh:mm:ss.mil.
error
is the error number of the last OSS Monitor error that occurred during an operation
on the server. See Numbered Messages on page A-38 for an explanation of a
specific error number.
error-detail
is the error number of the Guardian file-system error (if any) reported with the
error value. For information about Guardian file-system errors, see the Guardian
Procedure Errors and Messages Manual.
OSS Detailed Status SERVER server-devicename
State.................. state
StartTime.............. time1
LastError.............. error
ErrorDetail............ error-detail
ErrorTime.............. time2
LastControlSyncTime.... time3
AlterAfterSyncOrStart.. status
*CPU.................... processor1
*BackupCPU.............. processor2
*SQLTimeout............. time4
*InodeCache............. size1
InodeCacheInUse........ size2
MaxInodeCacheUsed...... size3
TimeMaxInodeCacheUsed.. time5
TimeMaxInodeCacheReset. time6
*LinkCache.............. size4
LinkCacheInUse......... size5
MaxLinkCacheUsed....... size6
TimeMaxLinkCacheUsed.... time7
TimeMaxLinkCacheReset... time8
Value Meaning
STARTED The server process is running.
STOPPED The server process is not running.