Open System Services Management and Operations Guide (G06.25+, H06.03+)

Messages
Open System Services Management and Operations Guide527191-002
A-12
FSCK Inconsistency and Error Messages
99
Cause. The FSCK utility has exhausted its internal memory.
Effect. FSCK terminates abnormally.
Recovery. Set the SAVEABEND attribute of the FSCK program file using the nld
command. Rerun FSCK to produce a saveabend file. Contact your service provider
and provide all relevant information as follows:
Saveabend file
OSS fileset catalog files
Description of the problem and accompanying symptoms
Details from the message or messages generated
Supporting documentation such as Event Management Service (EMS) logs, trace
files, and a processor dump, if applicable
If your local operating procedures require contacting the Global Customer Support
Center (GCSC), supply your system number and the numbers and versions of all
related products as well.
100
parent
indicates the inode number of the parent end of the link.
child
indicates the inode number of the child end of the link.
linkname
identifies the affected link.
Cause. The FSCK utility detected a corrupt record in the PXLINK file.
Effect. This record is not included in the new PXLINK file. Any inode orphaned as a
result is placed in the OSS /lost+found directory with the name #inode-number.
Recovery. If the REPAIR option was not specified or the REPAIR NONE option was
specified in the Subsystem Control Facility (SCF) DIAGNOSE FILESET command, the
catalog is still in an inconsistent state. Reissue the command with the REPAIR
SERIOUS or REPAIR OPEN option.
ERROR 99 - HEAP OVERFLOW
SERIOUS 100 - Corrupt PXLINK Record - Parent:parent,
Child:child, Name:linkname