Open System Services Management and Operations Guide (G06.25+, H06.03+)
Messages
Open System Services Management and Operations Guide—527191-002
A-41
Numbered Messages
Cause. A Subsystem Control Facility (SCF) ADD or ALTER command contained a
parameter value that was invalid.
Effect. The command is not processed.
Recovery. Reissue the command with a valid value.
6
Cause. A Subsystem Control Facility (SCF) command contained a parameter without
a required value or was missing a required parameter.
Effect. The command is not processed.
Recovery. Reissue the command with an appropriate parameter or value.
8
name
identifies the affected entity.
Cause. During the execution of a Subsystem Control Facility (SCF) command, an
OSS server had a recurring I/O error and the retry limit was reached. This error usually
occurs when either a processor fails, an OSS name server process is not running, or a
disk device is malfunctioning.
Effect. The OSS Monitor stops processing the command.
Recovery. Perform one or more of the following actions:
•
Try to determine and correct the cause of the I/O retries. If the failing entity is an
OSS name server, do one of the following:
°
If the OSS name server is still running, stop all filesets managed by that OSS
name server. Remount those filesets.
°
If the OSS name server is not running, stop and restart the OSS Monitor so
that it executes the automatic fileset restart sequence.
•
If a server processor has failed, bring the processor up, which should cause the
OSS Monitor to execute the automatic fileset restart sequence.
•
Execute the SCF command again.
OSS E00006 No attributes have been specified for this
command.
OSS E00008 Exceeded maximum I/O error retry limit on name