Open System Services Management and Operations Guide (G06.27+, H06.04+)
Operating the OSS Environment
Open System Services Management and Operations Guide—527191-003
2-11
Starting the OSS Monitor
Table 2-1. Currently Used TACL PARAMs for the OSS Monitor (page 1 of 2)
PARAM Description
AUTOSTART { AUTO | MANUAL } Specifies whether the automatic startup service 
should be used for any stopped servers or 
filesets that are configured to use that service.
This PARAM can provide the initial configuration 
value for the AUTOSTART attribute of the 
subsystem. If this PARAM is supplied after the 
first execution of the OSS Monitor, it replaces 
the current value for the AUTOSTART attribute 
of the subsystem.
This value is kept in the ZOSSPARM file and 
controlled through the SCF ALTER SUBSYS 
command. See ALTER SUBSYS, ALTER MON, 
and ALTER PROCESS Commands on 
page 12-34 for more information about the 
options that can be specified. 
OSS^FSCK^CPU processor Specifies which processor to use when the 
FSCK integrity-checker program performs fileset 
recovery.
This PARAM can provide the initial configuration 
value for the FSCKCPU attribute of the 
subsystem. If this PARAM is supplied after the 
first execution of the OSS Monitor, it replaces 
the current value for the FSCKCPU attribute of 
the subsystem.
This value is kept in the ZOSSPARM file and 
controlled through the SCF ALTER SUBSYS 
command. See ALTER SUBSYS, ALTER MON, 
and ALTER PROCESS Commands on 
page 12-34 for more information about the 
values that can be specified. 