Open System Services Management and Operations Guide (G06.29+, H06.07+)

Messages
Open System Services Management and Operations Guide527191-005
A-36
Numbered Messages
1
Cause. The OSS Monitor has detected a serious internal error during the execution of
a Subsystem Control Facility (SCF) command.
Effect. The OSS Monitor stops processing the command.
Recovery. Check the Event Management Service (EMS) log for related messages.
Contact your service provider and provide all relevant information as follows:
Description of the problem and accompanying symptoms
Details from the message or messages generated
Supporting documentation such as EMS logs, trace files, and a processor dump, if
applicable
If your local operating procedures require contacting the Global Customer Support
Center (GCSC), supply your system number and the numbers and versions of all
related products as well.
2
server-name
is the server name of the OSS name server affected by the error.
Cause. During the execution of a Subsystem Control Facility (SCF) command, the
OSS Monitor did not receive a response from an OSS name server process within the
time specified by the IOTIMEOUT attribute of the OSS subsystem. This might indicate
any of the following conditions:
The IOTIMEOUT attribute value is too small.
The OSS name server is overloaded with requests because of insufficient
processor or memory resources or because of a software problem.
Effect. The OSS Monitor stops processing the command.
Recovery. Perform one or more of the following actions, depending on how often the
message occurs:
Reissue the SCF command.
Use the SCF ALTER SUBSYS command to increase the value of the IOTIMEOUT
attribute.
OSS E00001 Internal error
OSS E00002 Server did not respond server-name