Open System Services Management and Operations Guide (G06.29+, H06.07+)

Messages
Open System Services Management and Operations Guide527191-005
A-38
Numbered Messages
Cause. A Subsystem Control Facility (SCF) ADD or ALTER command contained a
parameter value that was invalid.
Effect. The command is not processed.
Recovery. Reissue the command with a valid value.
6
Cause. A Subsystem Control Facility (SCF) command contained a parameter without
a required value or was missing a required parameter.
Effect. The command is not processed.
Recovery. Reissue the command with an appropriate parameter or value.
8
name
identifies the affected entity.
Cause. During the execution of a Subsystem Control Facility (SCF) command, an
OSS server had a recurring I/O error and the retry limit was reached. This error usually
occurs when either a processor fails, an OSS name server process is not running, or a
disk device is malfunctioning.
Effect. The OSS Monitor stops processing the command.
Recovery. Perform one or more of the following actions:
Try to determine and correct the cause of the I/O retries. If the failing entity is an
OSS name server, do one of the following:
°
If the OSS name server is still running, stop all filesets managed by that OSS
name server. Remount those filesets.
°
If the OSS name server is not running, stop and restart the OSS Monitor so
that it executes the automatic fileset restart sequence.
If a server processor has failed, bring the processor up, which should cause the
OSS Monitor to execute the automatic fileset restart sequence.
Execute the SCF command again.
OSS E00006 No attributes have been specified for this
command.
OSS E00008 Exceeded maximum I/O error retry limit on name