Open System Services Management and Operations Guide (G06.29+, H06.07+)
Messages
Open System Services Management and Operations Guide—527191-005
A-53
Numbered Messages
46
Cause. A Subsystem Control Facility (SCF) ALTER FILESET command attempted to
change the OSS name server process for a fileset while the fileset is mounted.
Effect. The command is not processed.
Recovery. Stop the fileset and any filesets mounted on it, then reissue the command
and restart all affected filesets.
47
Cause. The mount point pathname specified in a Subsystem Control Facility (SCF)
ADD FILESET or ALTER FILESET command was invalid or is a relative pathname.
Effect. The command is not processed.
Recovery. Determine the correct absolute pathname to use for the mount point, then
reissue the command.
48
Cause. The mount point pathname specified in a Subsystem Control Facility (SCF)
ADD FILESET or ALTER FILESET command begins with /E or /G.
Effect. The command is not processed.
Recovery. Select a mount point in the local node’s OSS file system and reissue the
command.
49
Cause. A record in the OSS Monitor database has been updated by a newer version
of the OSS monitor than is currently running. The record was updated in such a way
that the OSS monitor currently running cannot reliably interpret the record's contents.
Effect. The record is not accessible to the current OSS monitor.
Recovery. Upgrade to a later version of the OSS monitor.
OSS E00046 Alter Name Server of active fileset is not allowed
OSS E00047 Mount point pathname must be an absolute pathname
OSS E00048 Mount Point Pathname may not start with /E or /G
OSS E00049 OSSMON/Database Record version incompatibility