Open System Services Management and Operations Guide (G06.29+, H06.07+)
Messages
Open System Services Management and Operations Guide—527191-005
A-62
Startup Messages
coll_name
indicates the process name specified in the command.
error_number
indicates the Guardian file-system error returned by the underlying call to the
Guardian FILE_OPEN_ procedure. For more information about this error, refer to
the Guardian Procedure Errors and Messages Manual.
Cause. The specified collector is not accessible. The process might not be running.
Effect. OSSTTY is running. Event Management Service (EMS) messages are logged
to the default collector process, $0.
Recovery. This is an informative message only; no action is needed unless a specific
nondefault collector process is required by your site procedures. The OSSTTY process
can be stopped and restarted after the problem is corrected.
Cause. The OSSTTY command was entered with the -secure flag specified. The
-secure flag is only used when an EDIT file must be created as the specified output
redirection target; that condition does not exist.
Effect. OSSTTY is running. If the OUT parameter specified an existing EDIT file, its
security permissions are unchanged.
Recovery. This is an informative message only; no action is needed.
Cause. The OSSTTY command was entered with the -wrap flag specified. The
-wrap flag is only used when an EDIT file is the specified output redirection target;
that condition does not exist.
Effect. OSSTTY is running.
Recovery. This is an informative message only; no action is needed.
OSSTTY: ****Warning**** EMS Collector coll_name is not
accessible, error error_number, Using $0 as the EMS
collector.
OSSTTY: ****Warning**** The EDIT file specified in the OUT
parameter already exists or is a process, ignoring the
–secure option. Continuing...
OSSTTY: ****Warning**** The –wrap option has no effect when
OUT is a process. Continuing...