Open System Services Management and Operations Guide (G06.30+, H06.08+, J06.03+)

Cause
The Guardian FILE_RENAME_ procedure call could not be completed.
Effect
CVT did not rename the indicated file.
Recovery
Check the command and correct it as necessary.
***fsck needed -- subvolume.PXCKSTAT exists***
subvolume
identifies the affected subvolume.
Cause
There is a PXCKSTAT file on one of the subvolumes involved in processing the command. CVT
does not move catalogs to, from, or within a subvolume that contains a PXCKSTAT file—nor
does it purge a saved catalog from such a subvolume.
Effect
CVT terminates.
Recovery
Run the FSCK utility against the catalog before attempting the CVT command again.
***Incomplete Command***
Cause
The command entered was incomplete.
Effect
CVT terminates.
Recovery
Check the command and correct it as necessary.
***Internal Error***
Cause
CVT has detected an internal inconsistency.
Effect
CVT terminates.
Recovery
Enter the command again with the INSPECT SAVEABEND RUN option to produce a saveabend
file. Contact your service provider and provide all relevant information as follows:
Saveabend file
OSS fileset catalog files
Description of the problem and accompanying symptoms
Details from the message or messages generated
Supporting documentation such as Event Management Service (EMS) logs, trace files, and
a processor dump, if applicable
If your local operating procedures require contacting the Global Customer Support Center
(GCSC), supply your system number and the numbers and versions of all related products as
well.
***Invalid Serial Number*** - token
token
identifies the invalid value found in place of an FSCK serial number (FSN).
338 Messages