3
{ WARNING | ERROR } 3 - operation Error error-number (description) on
filename
operation
identifies the uncompleted operation.
error-number
provides the Guardian file-system error number of the error that occurred.
description
describes the error that occurred.
filename
identifies the affected file.
Cause
The FSCK utility encountered a file-management error on an operation (given by operation)
on the indicated file because of the error described by error-number and description.
Some common examples of this message are:
MeaningMessage
There is no OSS fileset catalog in the specified (or
implied) catalog subvolume. The ZOSSFSET file specifies
an incorrect volume.
OPEN Error 11 (Record Not Found) on PXINODE
Another copy of FSCK is checking the catalog.OPEN Error 12 (File In Use) on PXCKSTAT
The specified (or implied) catalog subvolume refers to a
nonexistent volume. The ZOSSFSET file specifies a
nonexistent volume.
OPEN Error 14 (No Such Device) on PXCKSTAT
Note that the severity of this message can be either WARNING or ERROR.
Effect
If the severity of the message is ERROR, FSCK terminates abnormally. If the severity of the error
is WARNING, FSCK attempts to recover from the error by retrying the operation.
Recovery
If the severity of the message is WARNING, the message is an informational message only; no
corrective action is needed.
If the severity of the message is ERROR, recovery actions depend on the specific cause of the
error. See the related Guardian file-system error explanation in the Guardian Procedure Errors
and Messages Manual for possible actions.
6
ERROR 6 - Catalog Version not supported by this program
Cause
The catalog is at a version higher than this version of the FSCK utility can handle. The catalog
was created by an incompatible version of the OSS file system, perhaps from a software release
version update (RVU) more recent than the RVU containing this copy of FSCK.
This message can indicate that you are attempting an operation on a D40 catalog using a
version of FSCK preceding the D30.02 RVU.
Effect
The FSCK utility terminates abnormally.
Recovery
Check that the correct catalog is being used. Use a more recent version of the OSS Monitor or
invoke a more recent version of FSCK.