Open System Services Management and Operations Guide (G06.30+, H06.08+, J06.03+)

16
WARNING 16 - Dirty Catalog using Fast Create; REPAIR ALL will be
performed
Cause
In a Subsystem Control Facility (SCF) DIAGNOSE FILESET command, the REPAIR option was
specified for a catalog that used the fast-create fileset option and had not been unmounted
cleanly.
Effect
The FSCK utility proceeds as if the REPAIR ALL option were selected, because catalogs that use
the fast-create option can be repaired only by using the REPAIR ALL option.
Recovery
Informational message only; no corrective action is needed.
98
ERROR 98 - INTERNAL ERROR
Cause
The FSCK utility detected a condition that indicates an internal logic error.
Effect
FSCK terminates abnormally.
Recovery
Set the SAVEABEND attribute of the FSCK program file using the nld command. Rerun FSCK
to produce a saveabend file. Contact your service provider and provide all relevant information
as follows:
Saveabend file
OSS fileset catalog files
Description of the problem and accompanying symptoms
Details from the message or messages generated
Supporting documentation such as Event Management Service (EMS) logs, trace files, and
a processor dump, if applicable
If your local operating procedures require contacting the Global Customer Support Center
(GCSC), supply your system number and the numbers and versions of all related products as
well.
99
ERROR 99 - HEAP OVERFLOW
Cause
The FSCK utility has exhausted its internal memory.
Effect
FSCK terminates abnormally.
Recovery
Set the SAVEABEND attribute of the FSCK program file using the nld command. Rerun FSCK
to produce a saveabend file. Contact your service provider and provide all relevant information
as follows:
Saveabend file
OSS fileset catalog files
Description of the problem and accompanying symptoms
FSCK Messages 343