-W[no]inspect Designates [does not designate] the Native Inspect debugger as the default
debugger for the output object file. Use this flag with the -g flag. The default set-
ting is -Wnoinspect. This flag is set only if an executable object file is produced.
-Wlines=n Sets the maximum number of lines on a listing page to n, if a listing is generated.
n is a number in the range 10 through 32767.
-W[no]list Temporarily enables [disables] the generation of the compiler listing. This flag
works only if the -Wnosuppress flag is specified. The default is -Wlist.
-W[no]map Temporarily enables [disables] the generation of identifier maps in the compiler
listing. This flag works only if the -Wnosuppress flag is specified. The default is
-Wnomap.
-Wmigration_check
When used with the -Wstandard=1985 flag, causes the compiler to issue a warning
message when it encounters a user-defined COBOL word that is a reserved word
in the COBOL-2002 standard. The default is not to issue migration warning mes-
sages.
-WmoduleCatalog="catalog_spec"
Specifies a NonStop SQL/MX module catalog name. The specified string is used
only if the input file does not contain an SQL/MX module directive or its module
directive does not specify a catalog name. The string cannot contain more than
128 characters.
This flag is valid only for preprocessor release 2.0 and newer.
-WmoduleGroup[="[group_spec]" ]
Specifies a string for a module group specification to use as a prefix to the module
name. The specified string is used only if the input file does not contain an
SQL/MX module directive or its module directive does not specify a group name.
The string cannot contain more than 31 characters.
This flag is valid only for preprocessor release 1.8 and newer.
-WmoduleSchema="schema_spec"
Specifies a NonStop SQL/MX module schema name. The specified string is used
only if the input file does not contain an SQL/MX module directive or its module
directive does not specify a schema name. The string cannot contain more than
128 characters.
This flag is valid only for preprocessor version 2.0 and newer.
-WmoduleTableSet[="[tableset_spec]" ]
Specifies a string for a tableset specification to use as the first suffix to the module
name. The specified string is used only if the input file does not contain an
SQL/MX module directive or its module directive does not specify a tableset
name The string cannot contain more than 31 characters.
This flag is valid only for preprocessor version 1.8 and newer.
-WmoduleVersion[="[version_spec]" ]
Specifies a string for a tableset specification to use as the second suffix to the
externally qualified module name that is written to the module file. The string
cannot contain more than 31 characters.
This flag is valid only for preprocessor release 1.8 and newer.