Open System Services System Calls Reference Manual (G06.29+, H06.08+, J06.03+)

select(2) OSS System Calls Reference Manual
The errno value [ETHNOTRUNNING] can be returned.
The time interval specified by the timeout parameter must meet these criteria:
The maximum interval is 2**31 seconds plus 2**31 microseconds. If a value
greater than this is specified, the maximum is used instead.
If a specified interval is not a whole multiple of 10 milliseconds, the next highest
whole multiple is used instead.
The use of this function with the POSIX User Thread Model library conforms to the following
industry standards:
IEEE Std 1003.1-2004, POSIX System Application Program Interface
714 Hewlett-Packard Company 527186-023