OSF DCE Administration Guide--Introduction

Installing DCE
7.2.2.4 Verifying the Ethernet Address
During installation, you may receive the following prompt to verify the machine’s 12-
digit hexadecimal Ethernet address:
The following IEEE 802 address has already
been entered for this machine:
0000c0eac744
Is this correct? (y)
You will receive this prompt under any of the following conditions:
If you are installing DCE for the first time
If you have used the dce_config REMOVE option to stop DCE daemons and remove
any data files associated with those daemons.
To answer the prompt, you have two choices:
If the displayed address is correct, press <RETURN>.
If the displayed address is incorrect,
1. Type n and press <RETURN>.
The dce_config script prompts for the correct address.
Enter your machine’s IEEE 802 address as a
12 digit hex number (for example, 08002B0F59BB):
2. Type the correct address and press <RETURN>.
The dce_config script continues the installation.
Note: If dce_config cannot obtain the machine’s Ethernet address, it will prompt
for the address without displaying an address to verify.
7.2.2.5 Installing OSF/1 Shared Libraries — For OSF/1 Machines Only
If you are installing DCE on an OSF/1 platform, the dce_config script prompts for
whether or not to install lib_admin, a tool to install and load the OSF/1 shared libraries,
by displaying:
Run /sbin/lib_admin? (y)
Type y to install the OSF/1 shared libraries or n to not install the libraries and press
<RETURN>. dce_config continues with the installation. If you plan to configure DCE,
you should answer yes to this question.