Error Messages and Status Codes
Severity: Warning Component: cds / cds_svc_server
Text: The timestamp on a new update is older than CDS_AllUpTo. Attribute =%s,
CDS_AllUpTo = %s, Update Timestamp = %s.
Explanation: An new update with a timestamp older then allupto was received. The
skulk operation will fail.
Action: Use the cdscp set dir to new epoch command to correct the problem.
0x10d0aa31 cds_s_server_towerfail_eb
Severity: Fatal Component: cds / cds_svc_server
Text: Unable to update local address set.
Explanation: The server was unable to construct an address for the local system and
update the clearinghouse’s location.
Action: Restart the DCE components.
0x10d0aa3b cds_s_server_unlink
Severity: Error Component: cds / cds_svc_server
Text: Unable to delete file %s: status = %ld.
Explanation: A call to the system function unlink(2) has failed.
Action: See the unlink(2) manual page for further details.
0x10d0aa2b cds_s_server_version_eb
Severity: Fatal Component: cds / cds_svc_server
Text: Unsupported version number specified on command line: %s.
Explanation: The -v switch was used with a version number the server doesn’t recognize.
Action: Use either -v 3.0 or -v 4.0.
0x10d0aa38 cds_s_server_write
Severity: Error Component: cds / cds_svc_server
Text: Unable to write to file %s: status = %ld.
Explanation: A call to the system function write(2) has failed.
Action: See the write(2) manual page for further details.
0x10d0aa5c cds_s_server_wrongstate
Severity: Notice Component: cds / cds_svc_server
Text: A replica of directory %s was in the wrong state %d.
Explanation: The state of a replica was not as expected.