OSF DCE Problem Determination Guide
OSF DCE Problem Determination Guide
Severity: Fatal Component: gds / GDS_S_CMX
Text: Parser: Maximum number of profile descriptions exceeded (maximum = %d) %s
Explanation: The program has detected a syntactically error in the NDS- configuration
source file.
Action: Provide a correct configuration file.
0x1260a7de GDS_S_NDS_NBGUID_ERR
Severity: Warning Component: gds / GDS_S_CMX
Text: Unique/group-ID for NETBIOS-address missing
Explanation: The program was not able to detect an unique/group identifier which must
be associated to a NETBIOS-address.
Action: Provide a correct NSAP-address.
0x1260a7df GDS_S_NDS_NBGUIDV_ERR
Severity: Warning Component: gds / GDS_S_CMX
Text: Invalid unique/group-ID for NETBIOS-address (id = %d, should be %d or %d)
Explanation: The program has detect an invalid unique/group identifier associated to the
NETBIOS-address.
Action: Provide a correct NSAP-address resp. NDS-configuration file.
0x1260a7e0 GDS_S_NDS_NBNAME_ERR
Severity: Warning Component: gds / GDS_S_CMX
Text: NETBIOS-name missing
Explanation: The program was not able to detect a NETBIOS-name which must be
associated to a NETBIOS-address.
Action: Provide a correct NSAP-address.
0x1260a7e1 GDS_S_NDS_NBNAMEV_ERR
Severity: Warning Component: gds / GDS_S_CMX
Text: Invalid NETBIOS-name (size = %d, maximum = %d)
Explanation: The program has detect an invalid NETBIOS-name associated to a
NETBIOS-address.
Action: Provide a correct NSAP-address resp. NDS-configuration file.
0x1260a7fe GDS_S_NDS_NETADDR
Severity: Warning Component: gds / GDS_S_CMX
Text: NOTICE: NSAP-address description entries decreased to %d (default value = %d)
2− 314 Tandem Computers Incorporated 124330