OSF DCE Problem Determination Guide
Error Messages and Status Codes
Severity: Varies Component: rpc
Text: Call ID in packet unknown
Explanation: An internal error occurred.
Action: Report the error to your vendor.
0x16c9a05e rpc_s_call_orphaned
Severity: Varies Component: rpc
Text: Call orphaned
Explanation: A client application has given up waiting for a manager routine to return.
This error occurs at the server but is usually not seen by the server application.
Action: None required.
0x16c9a067 rpc_s_call_queued
Severity: Varies Component: rpc
Text: Call queued
Explanation: An internal status code.
Action: None required.
0x16c9a06f rpc_s_calls_too_large_for_wk_ep
Severity: Varies Component: rpc
Text: Calls too large for well known endpoint
Explanation: The specified value of argument max_call_requests exceeds the maximum
allowed when using a well-known endpoint.
Action: Specify a max_call_requests value of rpc_c_protseq_max_reqs_default to
obtain the maximum value allowed for the specified protocol sequence.
0x16c9a06c rpc_s_call_timeout
Severity: Varies Component: rpc
Text: Call timed out
Explanation: A remote call did not return before the timeout set by
rpc_mgmt_set_call_timeout expired.
Action: None required.
0x16c9a030 rpc_s_cancel_timeout
Severity: Varies Component: rpc
Text: Cancel timeout
124330 Tandem Computers Incorporated 2−507