OSI PICS Manual
ISO 9542 for OSI/TS
Tandem OSI PICS Manual–135046
6-5
PICS Proforma: IS0 9542(1988) — Intermediate
System
PICS Proforma: IS0 9542(1988) — Intermediate
System
Tandem Implementation Note: Intermediate systems are not supported.
Item Are the Following PDUs Supported? Clauses Status Support
ESH-s <s> End System Hello 7.1, 7.5 M Yes
ESH-r <r> End System Hello 7.1, 7.5 CI:M Yes
ISH-r <r> Intermediate System Hello 7.1, 7.6 CI:M Yes
RD-r <r> Redirect 7.1, 7.7 RI:M Yes
Item Are the Following PDU Fields Supported? Clauses Status Support
FxPt <s> Fixed Part
<r> Fixed Part
7.2.1-7.2.7
7.2.1-7.2.7
M
(CIvRI):M
Ye s
Ye s
SA-sl <s> Source Address 7.3.1 M Yes
SA-rl <r> One NSAP only 7.3.2 CI:M Yes
SA-sm <s> Source Address 7.3.3 O Yes
SA-rm <r> Two or more NSAPS CI:M Yes
NET-r <r> Network Entity Title 7.3.1/2/4 (ClvRl):M Yes
DA-r <r> Destination Address 7.3.1/2/5 RI:M Yes
BSNPA-r <r> Subnetwork Address 7.3.1/2/6 Rl:M Yes
Scty-s <s> Security 7.4.2 O No
Scty-r <r> Security 7.4.2 O No
Pty-s <s> Priority 7.4.3 O No
Pty-r <r> Priority 7.4.3 O No
QoSM-r <r> QoS Maintenance 7.4.4 Rl:O No
AdMk-r <r> Address Mask 7.4.5 Rl:O No
SNMk-r <r> SNPA Mask 7.4.6 Rl:O No
ESCT-r <r> Suggested ES Configuration Timer 7.4.7 CI:O No
OOpt-r <r> (ignore) Unsupported or unknown options 7.4.1 M Yes
OOpt-s <s> Other options P No
Item Parameter Ranges Clauses Status Support
HTv What range of values can be set for the Holding
Time field in transmitted PDUs?
6.1,6.1.2 M From 1 second
to 655 seconds
by increments of
1 second
CTv If configuration information is supported what
range of values can be set for the Configuration
Timer?
6.1,6.1.1 Cl:M From 1 second
to 655 seconds
by increments of
1 second