OSI/AS and OSI/TS Supplement (Includes RFC-1006 Support)
General OSI/AS and OSI/TS Manual Changes and Corrections
107751 Tandem Computers Incorporated 8–13
2. some implementations require the binary value %H03010100 be included in the
CUD Field to identify the Transport entity
3. some implementations require another binary value of up to 16 bytes (or 32
characters) of user-defined information be specified.
OSI/TS users can now explicitly enable the sending of the transport protocol ID
%H03010100 or a CUD Field value of their choice.
The following exceptions apply:
Fast Select is not supported.
The Call User Data Field is always set to %H81000000 for the Subnetwork
Dependent Convergent Function (SNDCF).
The syntax of this PARAM is:
PARAM TSP^PROTO^ID [ ON | OFF |
value
]
value
can be an even number of hexadecimal digits between 2 to 32 digits in length. If
the TSP process detects an error in the value provided, it sets the TSP^PROTO^ID
to OFF.
Default: OFF
Examples:
PARAM TSP^PROTO^ID ON
This example sets the CUD field to identify the Transport entity to %H03010100.
PARAM TSP^PROTO^ID F1000000
This example sets the CUD field to identify the Transport entity to %HF1000000.
S 931116 1706 14562
Summary
The description of the ranges of values for the MAXCONNECTIONS attribute needs
clarifying.
Manuals Affected
SCF Reference Manual for Tandem OSI/TS
Tandem OSI/TS Management Programming Manual
Detailed Description
The description for MAXCONNECTIONS should read as follows: