OSI/AS Configuration and Management Manual

Troubleshooting Guide
OSI/AS Configuration and Management Manual424119-001
8-15
API Troubleshooting Example
The Inspect command
L5HALFO-d status
displays the following:
You can see that now no error is returned (ZAPS-VAL-STATUS-OK); the ATTACH
request completed successfully. Next you should call APS_STATUS_ to verify further.
After the following typical line of code
error := APS_STATUS_( cepi_1
, event_code
, device_name
, error_code
, error_subcode
, service_id
, diagnostic_buffer
, original_error_info
, transport_state
, transport_substate
);
the Inspect command
L5HALFO-d error_code
displays the following:
Clearly, no error has occurred (ZAPS-ERR-OK).
The Inspect command
L5HALFO-d device_name
displays the following:
The screen shows that the subdevice was registered by the OSI manager process.
STATUS= 0
ERROR_CODE= 0
DEVICE_NAME=
ZC=
BYTE[0]= "\" 249 "TAP2 #Z000017 "