OSI/AS Configuration and Management Manual

Troubleshooting Guide
OSI/AS Configuration and Management Manual424119-001
8-38
Troubleshooting Example
Step 1: Reset the Statistics Counters and Rerun the Application
Reset all the statistics counters. See Command File for Resetting Statistics Counters on
page 8-68.
Rerun the application. This ensures that the statistics screens are as free from irrelevant
information as possible, and makes it easier to identify information pertaining to the
particular problem you are trying to diagnose.
Step 2: Analyze the Application Using Inspect
The call to APS_STATUS_ determines the type of event (evt), and the name of the
subdevice (dev). After the following typical line of code
ret := aps_status_ ( cepi1, evt, dev, err, errsub, svcid,
diagnostic^buf, orig^err );
the Inspect command
display DEV
displays the following:
The screen shows that the TAPS process has configured the session ATTACH for
subdevice $TAP2.#Z000022.
DEV =
BYTE[0] = "\" 249 "TAP2 #Z000022 "