OSI/AS Management Programming Manual
ADD PROFILE Command
Commands and Responses
056785 Tandem Computers Incorporated 5–35
ZOSI-VAL-X25-NETID-DDXP Remote network is DDXP.
ZOSI-VAL-X25-NETID-X25NP No port number to be used.
ZOSI-VAL-X25-NETID-X25UD Port number is in user data field.
ZOSI-VAL-X25-NETID-X25XA Extended address format is used.
ZOSI-VAL-X25-NETID-X25SA Subaddress is used.
The default for the ZX25REMOTENET field is the NETID value from the
appropriate X.25 line.
ZX25THRUPUT
specifies the throughput class limit for X.25 networks. The value is entered as
the throughput class limit for calls received, followed by a comma, followed
by the throughput class limit for calls initiated. The range for both integers is
3 through 12. The default is the value for the X.25 line.
ZX25PVC
is the channel number of the permanent virtual circuit (PVC) to which the X.25
subdevice being added is bound. The range of values is 1 through 4095 for all
network types except TRANSPAC. The range of values for TRANSPAC
networks is 0 through 4095. The default is no PVC assigned.
ZIP-NULL-LAYER
controls the generation of the header for the inactive subset (the null Network
Layer) of the OSI internet protocol (IP). If this field is set to ZSPI-VAL-TRUE,
the inactive-subset header is enabled, and the full subset of the IP is disabled.
If it is set to ZSPI-VAL-FALSE, the inactive-subset header is disabled, and the
full subset of the IP is enabled. The default value is ZSPI-VAL-FALSE. See
“Operational Notes” for further information.
ZIP-X25-SNDCF
controls the the subnetwork dependent convergence facility (SNDCF). This
parameter is meaningful only if the Transport Layer protocol uses the OSI
internet protocol (IP) to communicate, via the SNDCF, with an X.25 network.
If this field is set to ZSPI-VAL-TRUE, the SNDCF is enabled; if it is set to ZSPI-
VAL-FALSE, the SNDCF is disabled. The default value is ZSPI-VAL-FALSE.
See “Operational Notes” for further information.