OSI/AS Management Programming Manual
ALTER SERVICE Command
Commands and Responses
056785 Tandem Computers Incorporated 5–89
ZOUTBOUND-CR-CONF-ERR-THLD
is the threshold value that the Transport Layer compares to the counter
ZOUTBOUND-CR-CONF-ERR. This counter records the number of times the
Transport Layer receives a disconnect request transport protocol data unit
(DR-TPDU) refusing a connect request because of negotiation failure,
duplicate source reference, mismatched references, reference overflow,
network connection refused, session entity not attached to TSAP, or address
unknown. OSI/TS generates a ZOS4-EVT-L4-THLD event message whenever
the counter value is nonzero and dividing the counter value by the threshold
value leaves a remainder of zero. The values range from 0 through 65535. If
the threshold is set to 0, L4-THLD event messages are never generated for this
counter. The value initially set by the OSI manager is 0.
ZINBOUND-CR-PROTO-ERR-THLD
is the threshold value that the Transport Layer compares to the counter
ZINBOUND-CR-PROTO-ERR. This counter records the number of times the
Transport Layer refuses a connect request because of a protocol error, invalid
header, invalid parameter length, or unspecified reason. OSI/TS generates a
ZOS4-EVT-L4-THLD event message whenever the counter value is nonzero
and dividing the counter value by the threshold value leaves a remainder of
zero. The values range from 0 through 65535. If the threshold is set to 0, L4-
THLD event messages are never generated for this counter. The value initially
set by the OSI manager is 0.
ZOUTBOUND-CR-ERR-THLD
is the threshold value that the Transport Layer compares to the counter
ZOUTBOUND-CR-ERR. This counter records the number of times the
Transport Layer times out while waiting for a response to a CR-TPDU, or that
it receives a DR-TPDU refusing a connect request because of a protocol error,
an invalid header or unspecified parameter, or an unspecified reason. OSI/TS
generates a ZOS4-EVT-L4-THLD event message whenever the counter value is
nonzero and dividing the counter value by the threshold value leaves a
remainder of zero. The values range from 0 through 65535. If the threshold is
set to 0, L4-THLD event messages are never generated for this counter. The
value initially set by the OSI manager is 0.
ZINBOUND-TPDU-PROTO-ERR-THLD
is the threshold value that the Transport Layer compares to the counter
ZINBOUND-TPDU-PROTO-ERR. This counter records the number of times
the Transport Layer receives a transport protocol data unit (TPDU), other than
a CR-TPDU, that can be associated with a transport connection and is invalid
or constitutes a protocol error. OSI/TS generates a ZOS4-EVT-L4-THLD event
message whenever the counter value is nonzero and dividing the counter
value by the threshold value leaves a remainder of zero. The values range
from 0 through 65535. If the threshold is set to 0, L4-THLD event messages are