OSI/AS Management Programming Manual

4: ZOSI-EVT-BKUP-DOWN
Event Messages
6–16 056785 Tandem Computers Incorporated
4: ZOSI-EVT-BKUP-DOWN This is a critical event. The primary process detected that the backup process is down.
The primary process attempts to create a new backup process unless the backup CPU
is down; in that case, it attempts to create a new backup when the CPU is reloaded.
Additional Unconditional Tokens
ZCOM-TKN-SUBJ-PROC token-type ZSPI-TYP-STRING.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZOSI-TKN-LOST-CAUSE token-type ZSPI-TYP-ENUM.
ZOSI-TKN-CPU* token-type ZZSPI-TYP-UINT.
* This is a conditional token.
Tandem Internal Tokens
None
Event-Message Text for C-series systems
process-name
, BACKUP Lost: Reason: [ Backup Stopped ]
[ Backup Abended ]
[ Backup CPU Down ]
[ Unknown ]
Event-Message Text for D-series systems
process-name
, BACKUP Down: Reason: [ Backup Stopped ]
[ Backup Abended ]
[ Backup CPU
cpu
Down ]
[ Unknown ]
Token Descriptions
ZCOM-TKN-SUBJ-PROC
is the Guardian 90 process name of the process that caused the event. It is the
subject of the message.
ZEMS-TKN-EMPHASIS
has the value ZSPI-VAL-TRUE, indicating that this is a critical event.
ZEMS-TKN-CONSOLE-PRINT
has the value ZSPI-VAL-TRUE, indicating that the EMS compatibility distributor
will route the event message to the designated operator console and, in compatible
mode, to the OPRLOG and any $AOPR process.