OSI/AS Management Programming Manual
8: ZOSI-EVT-SM-ERR
Event Messages
056785 Tandem Computers Incorporated 6–27
8: ZOSI-EVT-SM-ERR This is not a critical event. The OSI/AS subsystem detected an internal state-machine
error. The connection identified in the ZCOM-TKN-SUBJ-SU token has been aborted.
Additional Unconditional Tokens
ZCOM-TKN-SUBJ-SU token-type ZSPI-TYP-STRING.
ZOSI-TKN-SM* token-type ZSPI-TYP-ENUM.
ZOSI-TKN-SM-STATE* token-type ZSPI-TYP-INT.
ZOSI-TKN-SM-EVT* token-type ZSPI-TYP-INT.
ZOSI-TKN-SM-ACT* token-type ZSPI-TYP-INT.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
Tandem Internal Tokens
* Tokens marked with an asterisk (*) in the list above are
Tandem internal tokens.
Event-Message Text
su-name
, State Machine Error: SMid=
sm-id
, State=
sm-state
,
Event=
sm-event
,
Action=
sm-action
Token Descriptions
ZCOM-TKN-SUBJ-SU
is the name of the subdevice that caused the event. It is the subject of the message.
ZEMS-TKN-EMPHASIS
has the value ZSPI-VAL-FALSE, indicating that this is not a critical event.
ZEMS-TKN-CONSOLE-PRINT
has the value ZSPI-VAL-TRUE, indicating that the EMS compatibility distributor
will route the event message to the designated operator console and, in compatible
mode, to the OPRLOG and any $AOPR process.
Probable Cause
OSI/AS detected an internal state-machine error.
Recommended Action
Contact your Tandem representative. Provide a log of the event message.
Consideration
Only the TAPS process issues this message.