OSI/AS SCF Reference Manual

Table Of Contents
OSI/AS Trace Facility
OSI/AS SCF Reference Manual424121-001
3-33
OPEN Request
Manual. The value of this field should always be zero. If the field contains a
nonzero value, you may need to seek additional help.
OPEN Request
The following trace record is for Compaq internal use and is generated by the OSI
manager or TAPS process immediately after it validates and processes an open system-
message.
Reply Error
shows the file-system error returned to the process that issued the open system-
message. For possible values, see the System Procedure Errors and Messages
Manual. The value of this field should always be zero. If the field contains a
nonzero value, you may need to seek additional help.
System Message
This trace record is for Compaq internal use and is generated by the OSI manager or
TAPS process immediately after it receives a Guardian system message.
MsgCode
shows the code number identifying the received system message. The possible
values are
08:20:07.100 >000.000 #41 OPEN Req
Reply Error: 0
08:20:07.100 >000.000 #39 System Msg
Msg Code: -30
Value Meaning Value Meaning
-2 CPU down -32 CONTROL
-3 CPU up -33 SETMODE
-5 STOP -34 RESETSYNC
-6 ABEND -35 CONTROLBUF
-8 Network change -37 SETPARAM
-10 Set time -38 CANCEL
-11 Power on -40 DEVICEINFO
-12 NEWPROCESSNOWAIT
completion
-100 REMOTE CPU DOWN
-20 Break -101 PROCESS DEATH NOTICE