OSI/AS SCF Reference Manual

Table Of Contents
OSI/AS SCF Commands
OSI/AS SCF Reference Manual424121-001
2-42
ADD PROFILE #L3 Command
X25THRUPUT
specifies the throughput class limit for calls received (data transmission from the
called DTE) (integer1) and the throughput class limit for calls initiated (data
transmission from the calling DTE) (integer2). This attribute is used only for X.25
networks.
X25TRANSITDELAY
specifies the transit delay in the facility field of a call-request packet. This attribute
is used only for X.25 networks.
Value: 3 through 12 (for both integer1 and integer2
Default: Defaults to the value of the X25THRUPUT attribute in the
ALTER #L3 SERVICE command.
Note that these values are based on the CCITT X.25
recommendations for 1980 and 1984.
Value
Bits per
Second
375
4 150
5 300
6 600
7 1200
8 2400
9 4800
10 9600
11 19200
12 48000
Value: 0.000 through 65.530 (0 through 65.53 seconds)
Default: Defaults to the value of the X25TRANSITDELAY attribute
in the ALTER #L3 SERVICE command.