OSI/FTAM and OSI/APLMGR SCF Reference Manual

PTrace Reference for Tandem FTAM
OSI/FTAM and OSI/APLMGR SCF Reference Manual421943-001
5-21
PROV Assoc Request
Status Code
is the APS status code returned to the initiator from OSI/AS. See the Tandem
OSI/AS Programming Manual for status code values.
Original: Error Code x Subcode x
is the error code and subcode generated at the presumed source of the error—the
source can be any of the underlying subsystems. See the Tandem OSI/FTAM
Programming Reference Manual, the Tandem OSI/AS Programming Manual, or the
OSI/TS Configuration and Management Manual for more information on error
codes and subcodes.
Current: Error Code x Subcode x
is the APS error code and subcode returned by OSI/AS. See the Tandem OSI/AS
Programming Manual for more information on error codes and subcodes.
Connection Result
is the ACSE connection result returned in ZAPS-VAL-CON-xxx. This field always
displays novalue because this trace record is issued before a connection result is
returned.
Local Application Address
is the local address of the application by specifying the common name or all of the
following address components: PSEL, SSEL, TSEL, and NSAP.
PDU Length
is the length of the protocol data unit (PDU), in bytes.
PDU Data
is a hexadecimal dump of the PDU, which is encoded using the Basic Encoding
Rules (BER) guidelines. Following the hexadecimal dump is a partial decoding of
the PDU into individual fields, with the contents of the field values left in the
BER-encoded format.