OSI/FTAM and OSI/APLMGR SCF Reference Manual

SCF Commands for Tandem FTAM
OSI/FTAM and OSI/APLMGR SCF Reference Manual421943-001
3-16
ADD PROFILE Errors
ADD PROFILE Errors
The following table lists the most common errors that can occur during the processing of
the ADD PROFILE command:
For more information on errors specific to APLMGR (OSIAPLMG errors having
positive error numbers), see Appendix B, SCF Error Messages for the APLMGR
Subsystem. For more information on common SCF error messages (errors having
negative error numbers), see the Subsystem Control Facility (SCF) Reference Manual
(for D-series releases) or the SCF Reference Manual for G-Series Releases.
Message Description
Expecting an existing SCF supported object
name or the character “(“
No APLMGR process by the specified name
could be found. To display valid APLMGR
process names, use the following command:
LISTDEV OSIAPLMG
OSIAPLMG E-00015
Object object-name already defined
The profile-name specified is already
registered. Reenter the command with a new
profile-name or use the ALTER
command to change the attributes of the
existing profile.
TOSIAPLMG E-00019 Invalid object name:
$name.#FTC.process-name
Do not use process-name when
specifying the alternate collector. To specify
the alternate collector, use
$name.#FTC
CP E-00022
Security Violation for process-name
You are not allowed to perform sensitive
commands. For further information on
sensitive commands, see Sensitive and
Nonsensitive Commands on page 1-9.
OSIAPLMG E00503 Missing Required
Attribute: attribute-name
The SCF command issued is missing the
required attribute. Reissue the command,
including the attribute.