Sensitive and Nonsensitive SCF Commands
Sensitive and Nonsensitive SCF Commands
Sensitive and nonsensitive commands regulate access to Tandem FTAM management
capabilities. Sensitive commands allow only certain users to change the state or
configuration of objects, start or stop tracing, or reset the values of statistics counters.
Nonsensitive commands allow any user to view requested information but not to alter
data.
Security is maintained by restricting the use of sensitive commands to members of the
Guardian super ID group and members of the Guardian user group that owns the
Tandem FTAM process (APLMGR, initiator, or responder) to which the command is
sent. (Use of commands directed to an initiator or a responder through the APLMGR
process is restricted based on the ownership of the APLMGR process.) Table 2-2
lists
the sensitive and nonsensitive SCF commands for Tandem FTAM.
SUSPEND Changes the state of an object from STARTED to
SUSPENDED.
PROCESS
TRACE Starts, modifies, or stops the gathering of trace
data.
PROCESS
VERSION Displays information about the product version. null
SUBSYS
Table 2-2. Sensitive and Nonsensitive SCF Commands
Sensitive Commands Nonsensitive Commands
ABORT INFO
ACTIVATE LISTOPENS
ADD NAMES
ALLOWOPENS STATS*
ALTER STATUS
DELETE VERSION
START
STATS, RESET*
STOP
STOPOPENS
SUSPEND
TRACE
* The STATS command is sensitive only when used with the RESET option.
RESET directs the command to reset all statistical counters for the object.
Table 2-1. SCF Commands and Associated Object Types (page 2 of 2)
Command Function
Applicable Object
Types